{"_buckets": {"deposit": "8edf7126-8532-480b-a9ae-9cfc65437d44"}, "_deposit": {"created_by": 2, "id": "9789", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "9789"}, "status": "published"}, "_oai": {"id": "oai:gunma-u.repo.nii.ac.jp:00009789", "sets": ["860"]}, "author_link": ["39930", "39931", "39938", "39934", "39933", "39932", "39935", "39936", "39937"], "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-05-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "127", "bibliographicPageStart": "121", "bibliographicVolumeNumber": "69", "bibliographic_titles": [{"bibliographic_title": "The Kitakanto medical journal = 北関東医学"}]}]}, "item_6_description_39": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Journal Article", "subitem_description_type": "Other"}]}, "item_6_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Objective: [123I] N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-[123I]iodophenyl) nortropane (123I-FP-CIT) or dopamine transporter (DAT) SPECT scan quantitatively depicts striatum dopamine transporter density. The specific binding ratio (SBR) is important for Parkinson\u0027s disease (PD) diagnosis. Correction techniques may improve 123I-FP-CIT image quality, but they are currently not standardized. We aim to determine attenuation correction (AC) and scatter correction (SC) influence on 123I-FP-CIT quantitative analysis.\nMethods: We preformed SPECT imaging on a striatal phantom representing striatum-to-background ratios ranging from 10:1 to 1:1. We used the Chang method for AC and triple energy window for SC. Commercially available software semi-automatically calculated SBR. We performed correlation analysis between SBR and the actual concentration ratio in four groups: no correction (NC), SC, AC, and combined correction (CC), paying particular attention to SBR values below the clinical cut-off (4.5). We applied the same imaging conditions, reconstruction, and corrections on 49 human 123I-FP-CIT SPECT studies. Asymmetric index values (AI) were also analyzed. Receiver operating characteristic (ROC) analysis provided AI diagnostic cut-off values in PD patients. PD patient population whose AI values were above these cut-off value were subject to a correlation study to confirm the association between their clinical symptoms and 123I-FP-CIT SPECT.\nResults: Phantom study. AC or CC increased SBR 123I-FP-CIT SPECT, making them very close to the standard ratios (AC: y=1.19x - 0.7; R2=0.98; CC: y=1.4x - 1.2; R2=0.98), while NC and SC underestimated SBR at lower values (1 to 4). Clinical study. There was no difference in SBR between NC and SC, while AC and CC produced significantly higher SBR than NC (p\u003c0.0001). Only SC affected AI values (p\u003c0.05). The association between clinical symptoms and 123I-FP-CIT imaging results were maintained only when either NC (n=12, p\u003c0.05) or CC (n=14, p\u003c0.05) was applied.\nConclusions: AC increased SBR more than other corrections, while SC increased AI value more than other corrections. The association between clinical symptom and SPECT findings were maintained when either NC or CC was applied. These correction methods should be carefully selected for 123I-FP-CIT SPECT brain imaging.", "subitem_description_type": "Abstract"}]}, "item_6_publisher_32": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "北関東医学会"}]}, "item_6_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1343-2826", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10585677", "subitem_source_identifier_type": "NCID"}]}, "item_6_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kanzaki, Takao"}], "nameIdentifiers": [{"nameIdentifier": "39930", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tran, Vu Quynh Vy"}], "nameIdentifiers": [{"nameIdentifier": "39931", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Higuchi, Tetsuya"}], "nameIdentifiers": [{"nameIdentifier": "39932", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakajima, Takahito"}], "nameIdentifiers": [{"nameIdentifier": "39933", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Achmad, Arifudin"}], "nameIdentifiers": [{"nameIdentifier": "39934", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, Yasuyuki"}], "nameIdentifiers": [{"nameIdentifier": "39935", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Taketomi-Takahashi, Ayako"}], "nameIdentifiers": [{"nameIdentifier": "39936", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suto, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "39937", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsushima, Yoshito"}], "nameIdentifiers": [{"nameIdentifier": "39938", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2023-03-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "69_121.pdf", "filesize": [{"value": "454.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 454600.0, "url": {"label": "69_121.pdf", "url": "https://gunma-u.repo.nii.ac.jp/record/9789/files/69_121.pdf"}, "version_id": "fe7385c2-ab2d-4e59-ab3c-9206682337d9"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Attenuation correction; Scatter correction", "subitem_subject_scheme": "Other"}, {"subitem_subject": "DAT scan", "subitem_subject_scheme": "Other"}, {"subitem_subject": "SBR", "subitem_subject_scheme": "Other"}, {"subitem_subject": "AI (asymmetric index)", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "The Influence of Attenuation and Scatter Corrections on Quantitative Analysis of 123I-FP-CIT SPECT Brain Imaging", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "The Influence of Attenuation and Scatter Corrections on Quantitative Analysis of 123I-FP-CIT SPECT Brain Imaging"}]}, "item_type_id": "6", "owner": "2", "path": ["860"], "permalink_uri": "http://hdl.handle.net/10087/00014023", "pubdate": {"attribute_name": "公開日", "attribute_value": "2023-03-23"}, "publish_date": "2023-03-23", "publish_status": "0", "recid": "9789", "relation": {}, "relation_version_is_last": true, "title": ["The Influence of Attenuation and Scatter Corrections on Quantitative Analysis of 123I-FP-CIT SPECT Brain Imaging"], "weko_shared_id": -1}
The Influence of Attenuation and Scatter Corrections on Quantitative Analysis of 123I-FP-CIT SPECT Brain Imaging
http://hdl.handle.net/10087/00014023
http://hdl.handle.net/10087/00014023050592c1-1f73-4573-9679-96be8c42d824
名前 / ファイル | ライセンス | アクション |
---|---|---|
69_121.pdf (454.6 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2023-03-23 | |||||
タイトル | ||||||
タイトル | The Influence of Attenuation and Scatter Corrections on Quantitative Analysis of 123I-FP-CIT SPECT Brain Imaging | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Attenuation correction; Scatter correction | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | DAT scan | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | SBR | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | AI (asymmetric index) | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Kanzaki, Takao
× Kanzaki, Takao× Tran, Vu Quynh Vy× Higuchi, Tetsuya× Nakajima, Takahito× Achmad, Arifudin× Takahashi, Yasuyuki× Taketomi-Takahashi, Ayako× Suto, Takayuki× Tsushima, Yoshito |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objective: [123I] N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-[123I]iodophenyl) nortropane (123I-FP-CIT) or dopamine transporter (DAT) SPECT scan quantitatively depicts striatum dopamine transporter density. The specific binding ratio (SBR) is important for Parkinson's disease (PD) diagnosis. Correction techniques may improve 123I-FP-CIT image quality, but they are currently not standardized. We aim to determine attenuation correction (AC) and scatter correction (SC) influence on 123I-FP-CIT quantitative analysis. Methods: We preformed SPECT imaging on a striatal phantom representing striatum-to-background ratios ranging from 10:1 to 1:1. We used the Chang method for AC and triple energy window for SC. Commercially available software semi-automatically calculated SBR. We performed correlation analysis between SBR and the actual concentration ratio in four groups: no correction (NC), SC, AC, and combined correction (CC), paying particular attention to SBR values below the clinical cut-off (4.5). We applied the same imaging conditions, reconstruction, and corrections on 49 human 123I-FP-CIT SPECT studies. Asymmetric index values (AI) were also analyzed. Receiver operating characteristic (ROC) analysis provided AI diagnostic cut-off values in PD patients. PD patient population whose AI values were above these cut-off value were subject to a correlation study to confirm the association between their clinical symptoms and 123I-FP-CIT SPECT. Results: Phantom study. AC or CC increased SBR 123I-FP-CIT SPECT, making them very close to the standard ratios (AC: y=1.19x - 0.7; R2=0.98; CC: y=1.4x - 1.2; R2=0.98), while NC and SC underestimated SBR at lower values (1 to 4). Clinical study. There was no difference in SBR between NC and SC, while AC and CC produced significantly higher SBR than NC (p<0.0001). Only SC affected AI values (p<0.05). The association between clinical symptoms and 123I-FP-CIT imaging results were maintained only when either NC (n=12, p<0.05) or CC (n=14, p<0.05) was applied. Conclusions: AC increased SBR more than other corrections, while SC increased AI value more than other corrections. The association between clinical symptom and SPECT findings were maintained when either NC or CC was applied. These correction methods should be carefully selected for 123I-FP-CIT SPECT brain imaging. |
|||||
書誌情報 |
The Kitakanto medical journal = 北関東医学 巻 69, 号 2, p. 121-127, 発行日 2019-05-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1343-2826 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10585677 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 北関東医学会 | |||||
資源タイプ | ||||||
内容記述タイプ | Other | |||||
内容記述 | Journal Article |