Item type |
学術雑誌論文 / Journal Article(1) |
公開日 |
2008-01-24 |
タイトル |
|
|
タイトル |
ArFエキシマレーザを用いたレーザ誘起蛍光法による拡散火炎内のNO計測 |
タイトル |
|
|
タイトル |
NO Measurement in Diffusion Flames by a Laser Induced Fluorescence Method with ArF Excimer Laser |
|
言語 |
en |
言語 |
|
|
言語 |
jpn |
その他のタイトル |
|
|
その他のタイトル |
NO Measurement in Diffusion Flames by a Laser Induced Fluorescence Method with ArF Excimer Laser |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Diffusion Combustion |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Spectroscopic Measurement |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Laser |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Soot |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Laser Induced Fluorescence |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
Excimer Laser |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
著者 |
新井, 雅隆
天谷, 賢児
長倉, 邦仁
|
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Laser induced fluorescence method was applied for the measurement of NO concentration in the propane and methane diffusion flames. A tunable, narrow band ArF excimer laser was used to excite the D (υ′=0) ←X (υ″=1) band of NO molecule. Emission spectrum of the induced light by a laser beam was measured by a spectroscope. Spectrum of the induced light from the diffusion flame was compared with that of the premixed flame. Although the spectrum had only NO fluorescence components on premixed flame, a lot of strong spectrum components related to the laser induced incandescence of the soot and laser induced breakdown appeared in the spectrum from the diffusion flame. NO fluorescence component was picked out from the emission spectrum with traversing the irradiate position of laser beam in order to obtain the accurate distribution of NO fluorescence on the flame axis. In this paper this method was named as S-LIF method. A planer laser induced fluorescence (P-LIF) method was tried to measure the distribution of NO fluorescence on the flame axis. In the P-LIF method, an interference filter was used to remove the obstructive light component from the LIF image. NO fluorescence distribution measured by P-LIF method was compared with that of S-LIF method. As the result, the P-LIF image qualitatively agreed with the data of S-LIF. It was confirmed that the interference filter did not remove completely the obstructive light components. |
書誌情報 |
日本機械学會論文集. B編
巻 64,
号 622,
p. 1925-1931,
発行日 1998-06-25
|
ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0387-5016 |
書誌レコードID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AN00187441 |
権利 |
|
|
権利情報 |
日本機械学会 |
権利 |
|
|
権利情報 |
本文データは学協会の許諾に基づきCiNiiから複製したものである |
フォーマット |
|
|
内容記述タイプ |
Other |
|
内容記述 |
application/pdf |
著者版フラグ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
出版者 |
|
|
出版者 |
日本機械学会 |
資源タイプ |
|
|
内容記述タイプ |
Other |
|
内容記述 |
Journal Article |
異版である |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
URI |
|
|
関連識別子 |
http://ci.nii.ac.jp/naid/110002397017/ |
更新日 |
|
|
日付 |
2017-03-27 |
|
日付タイプ |
Created |