{"created":"2023-06-19T08:36:46.309724+00:00","id":3245,"links":{},"metadata":{"_buckets":{"deposit":"f861b924-c833-4fc6-b1ea-4e82316f0d28"},"_deposit":{"created_by":2,"id":"3245","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"3245"},"status":"published"},"_oai":{"id":"oai:gunma-u.repo.nii.ac.jp:00003245","sets":["572:575:576"]},"author_link":["7751","7753","7750","7754","7752","7749"],"item_6_alternative_title_18":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Analyses on a Declining Performance of PEMFC with Fuel Containing Impurities : 2nd Report, Characteristic Evaluation of Methanol Reforming Type Fuel Cells"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-11-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"687","bibliographicPageEnd":"2559","bibliographicPageStart":"2553","bibliographicVolumeNumber":"69","bibliographic_titles":[{"bibliographic_title":"日本機械学會論文集. B編"}]}]},"item_6_date_61":{"attribute_name":"更新日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-03-27","subitem_date_issued_type":"Created"}]},"item_6_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_6_description_39":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_6_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper covers our investigation into a decline in performance resulting from use of fuel containing impurities in methanol reforming type FCs. The investigations conducted and their results are as follows : 1) Various experiments and analyses were conducted to determine the adverse effects of CO, HCHO, HCOOH, and CH_4 on the performance of the FC ; 2) In the case of HCHO and HCOOH poisoning, performance became worse when Ru was added to the FC catalytic-electrode ; 3) The quantities of the partial pressure decline phenomenon of hydrogen gas caused by mixing CO_2 and N_2 gases appeared to be the same ; 4) The progress of poisoning with the reforming gas was complex ; however, explanation became possible by taking CO poisoning and the influence of the partial pressure decline phenomenon of hydrogen gas into consideration.","subitem_description_type":"Abstract"}]},"item_6_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会"}]},"item_6_relation_43":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":" http://ci.nii.ac.jp/naid/110002388413/","subitem_relation_type_select":"URI"}}]},"item_6_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本機械学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_6_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5016","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00187441","subitem_source_identifier_type":"NCID"}]},"item_6_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"成澤, 和幸"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"林田, 守正"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"倉嶌, 大輔"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"室岡, 絢司"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"若林, 克彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"紙屋, 雄史"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-11-25"}],"displaytype":"detail","filename":"B69_2553.pdf","filesize":[{"value":"623.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"B69_2553.pdf","url":"https://gunma-u.repo.nii.ac.jp/record/3245/files/B69_2553.pdf"},"version_id":"231322a8-c534-48a8-861e-ee3da592ef6d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Fuel Cell","subitem_subject_scheme":"Other"},{"subitem_subject":"Electric Vehicle","subitem_subject_scheme":"Other"},{"subitem_subject":"Catalyst","subitem_subject_scheme":"Other"},{"subitem_subject":"Methanol","subitem_subject_scheme":"Other"},{"subitem_subject":"Reformer","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"固体高分子形燃料電池における不純物被毒の分析 : 第2報, 被毒予測式と被毒係数を用いたメタノール改質ガス被毒の評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"固体高分子形燃料電池における不純物被毒の分析 : 第2報, 被毒予測式と被毒係数を用いたメタノール改質ガス被毒の評価"},{"subitem_title":"Analyses on a Declining Performance of PEMFC with Fuel Containing Impurities : 2nd Report, Characteristic Evaluation of Methanol Reforming Type Fuel Cells","subitem_title_language":"en"}]},"item_type_id":"6","owner":"2","path":["576"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-01-18"},"publish_date":"2008-01-18","publish_status":"0","recid":"3245","relation_version_is_last":true,"title":["固体高分子形燃料電池における不純物被毒の分析 : 第2報, 被毒予測式と被毒係数を用いたメタノール改質ガス被毒の評価"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-06-19T13:07:24.588085+00:00"}