{"created":"2023-06-19T08:36:47.161735+00:00","id":3261,"links":{},"metadata":{"_buckets":{"deposit":"9763d037-38d6-4458-a5d1-6139a1622141"},"_deposit":{"created_by":2,"id":"3261","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"3261"},"status":"published"},"_oai":{"id":"oai:gunma-u.repo.nii.ac.jp:00003261","sets":["572:575:576"]},"author_link":["7825","7826","7824","7827"],"item_6_alternative_title_18":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Measurement of Fuel Concentration Distribution in a Sooting Flame through Raman Scattering"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-05-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"705","bibliographicPageEnd":"1452","bibliographicPageStart":"1445","bibliographicVolumeNumber":"71","bibliographic_titles":[{"bibliographic_title":"日本機械学會論文集. B編"}]}]},"item_6_date_61":{"attribute_name":"更新日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-03-27","subitem_date_issued_type":"Created"}]},"item_6_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_6_description_39":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Journal Article","subitem_description_type":"Other"}]},"item_6_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Raman scattering technique with KrF excimer laser was applied to obtain a fuel concentration distribution in a sooting flame. In the case of sooting flame, fluorescence from polycyclic aromatic hydrocarbons (PAH) and laser-induced incandescence (LII) from soot particles appeared with Raman scattering. These background emissions overlappped on the Raman scattering. In order to separate the Raman scattering and the background emissions, polarization property of laser-induced emissions was utilized. Since the background emissions were depolarized whereas the Raman scattering was highly polarized, it is possible to subtract the background emissions from the overlapping signal of the Raman scattering and the background emissions. Subtracting the emission signals for the electric vector of the laser light perpendicular and parallel to the direction of observation allows to extract the precise Raman signals. By using this technique, detailed fuel concentration distribution in sooting flames could be obtained based on Raman scattering.","subitem_description_type":"Abstract"}]},"item_6_publisher_32":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会"}]},"item_6_relation_43":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":" http://ci.nii.ac.jp/naid/110005051554/","subitem_relation_type_select":"URI"}}]},"item_6_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本機械学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_6_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5016","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00187441","subitem_source_identifier_type":"NCID"}]},"item_6_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"林田, 和宏"}],"nameIdentifiers":[{"nameIdentifier":"7824","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"天谷, 賢児"}],"nameIdentifiers":[{"nameIdentifier":"7825","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤, 桂司"}],"nameIdentifiers":[{"nameIdentifier":"7826","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"新井, 雅隆"}],"nameIdentifiers":[{"nameIdentifier":"7827","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-11-25"}],"displaytype":"detail","filename":"B71_1445.pdf","filesize":[{"value":"819.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"B71_1445.pdf","url":"https://gunma-u.repo.nii.ac.jp/record/3261/files/B71_1445.pdf"},"version_id":"1a9d0245-c179-45f2-92c3-0002ae3a6f69"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Spectroscopic Measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"Laser","subitem_subject_scheme":"Other"},{"subitem_subject":"Flame","subitem_subject_scheme":"Other"},{"subitem_subject":"Combustion","subitem_subject_scheme":"Other"},{"subitem_subject":"Raman Scattering","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ラマン散乱法による輝炎内の燃料濃度分布測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ラマン散乱法による輝炎内の燃料濃度分布測定"},{"subitem_title":"Measurement of Fuel Concentration Distribution in a Sooting Flame through Raman Scattering","subitem_title_language":"en"}]},"item_type_id":"6","owner":"2","path":["576"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-01-24"},"publish_date":"2008-01-24","publish_status":"0","recid":"3261","relation_version_is_last":true,"title":["ラマン散乱法による輝炎内の燃料濃度分布測定"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-06-19T13:06:55.955043+00:00"}