ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 30 医学系研究科
  2. 3005 北関東医学会
  3. 330501 The Kitakanto medical journal
  4. Vol.69 No.2(2019)

The Influence of Attenuation and Scatter Corrections on Quantitative Analysis of 123I-FP-CIT SPECT Brain Imaging

http://hdl.handle.net/10087/00014023
http://hdl.handle.net/10087/00014023
050592c1-1f73-4573-9679-96be8c42d824
名前 / ファイル ライセンス アクション
69_121.pdf 69_121.pdf (454.6 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2023-03-23
タイトル
タイトル The Influence of Attenuation and Scatter Corrections on Quantitative Analysis of 123I-FP-CIT SPECT Brain Imaging
言語
言語 eng
キーワード
主題Scheme Other
主題 Attenuation correction; Scatter correction
キーワード
主題Scheme Other
主題 DAT scan
キーワード
主題Scheme Other
主題 SBR
キーワード
主題Scheme Other
主題 AI (asymmetric index)
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kanzaki, Takao

× Kanzaki, Takao

WEKO 39930

Kanzaki, Takao

Search repository
Tran, Vu Quynh Vy

× Tran, Vu Quynh Vy

WEKO 39931

Tran, Vu Quynh Vy

Search repository
Higuchi, Tetsuya

× Higuchi, Tetsuya

WEKO 39932

Higuchi, Tetsuya

Search repository
Nakajima, Takahito

× Nakajima, Takahito

WEKO 39933

Nakajima, Takahito

Search repository
Achmad, Arifudin

× Achmad, Arifudin

WEKO 39934

Achmad, Arifudin

Search repository
Takahashi, Yasuyuki

× Takahashi, Yasuyuki

WEKO 39935

Takahashi, Yasuyuki

Search repository
Taketomi-Takahashi, Ayako

× Taketomi-Takahashi, Ayako

WEKO 39936

Taketomi-Takahashi, Ayako

Search repository
Suto, Takayuki

× Suto, Takayuki

WEKO 39937

Suto, Takayuki

Search repository
Tsushima, Yoshito

× Tsushima, Yoshito

WEKO 39938

Tsushima, Yoshito

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective: [123I] N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-[123I]iodophenyl) nortropane (123I-FP-CIT) or dopamine transporter (DAT) SPECT scan quantitatively depicts striatum dopamine transporter density. The specific binding ratio (SBR) is important for Parkinson's disease (PD) diagnosis. Correction techniques may improve 123I-FP-CIT image quality, but they are currently not standardized. We aim to determine attenuation correction (AC) and scatter correction (SC) influence on 123I-FP-CIT quantitative analysis.
Methods: We preformed SPECT imaging on a striatal phantom representing striatum-to-background ratios ranging from 10:1 to 1:1. We used the Chang method for AC and triple energy window for SC. Commercially available software semi-automatically calculated SBR. We performed correlation analysis between SBR and the actual concentration ratio in four groups: no correction (NC), SC, AC, and combined correction (CC), paying particular attention to SBR values below the clinical cut-off (4.5). We applied the same imaging conditions, reconstruction, and corrections on 49 human 123I-FP-CIT SPECT studies. Asymmetric index values (AI) were also analyzed. Receiver operating characteristic (ROC) analysis provided AI diagnostic cut-off values in PD patients. PD patient population whose AI values were above these cut-off value were subject to a correlation study to confirm the association between their clinical symptoms and 123I-FP-CIT SPECT.
Results: Phantom study. AC or CC increased SBR 123I-FP-CIT SPECT, making them very close to the standard ratios (AC: y=1.19x - 0.7; R2=0.98; CC: y=1.4x - 1.2; R2=0.98), while NC and SC underestimated SBR at lower values (1 to 4). Clinical study. There was no difference in SBR between NC and SC, while AC and CC produced significantly higher SBR than NC (p<0.0001). Only SC affected AI values (p<0.05). The association between clinical symptoms and 123I-FP-CIT imaging results were maintained only when either NC (n=12, p<0.05) or CC (n=14, p<0.05) was applied.
Conclusions: AC increased SBR more than other corrections, while SC increased AI value more than other corrections. The association between clinical symptom and SPECT findings were maintained when either NC or CC was applied. These correction methods should be carefully selected for 123I-FP-CIT SPECT brain imaging.
書誌情報 The Kitakanto medical journal = 北関東医学

巻 69, 号 2, p. 121-127, 発行日 2019-05-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1343-2826
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN10585677
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
出版者
出版者 北関東医学会
資源タイプ
内容記述タイプ Other
内容記述 Journal Article
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 09:53:23.315390
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3